Safe and Stable
Advanced Flat Panel Detector (FPD)
Excellent Clinical Images
Humanized Design
X1 1. Up and down movement range of the cassette along the column: 400mm-1850mmwith a deviation of not more than ±5%,and mechanical limit. 2. Size dimensions of thecassette: 530 x 494 x 75mm 3. Able to clamp various models of flat panel detectors and cassette dimensions 4. The grid can be installed on the side(498.5 x 449mm). 5. Overall height of the chest radiograph stand column: 2060mm. 6. Up and down movement handbrake and hand release automatic brake. X2 1.Movement:350mm-1850mm. 2. Operation mode: manualand electromagnetic brake. 3. Cassette dimensions: 17*17 detector 4. With AEC ionization chamber assembly position and grid insertion position. 5. Able to detect the presence or absence of grids: yes. 6. Able to detect the presence or absence of detectors: yes. 7.Dimensions:380x530x2200Mm(length x width x height). 8. Equipped with a potentiometer for measuring up and down movement. X3 1.Movement: 350mm-1850mm 2. Operation mode: manual and electric integration, at60mm/s 3. Cassette dimensions: 17*17 detector 4. With AEC ionization chamber assembly position and grid insertion position 5. Power-off protection function: yes 6. Able to detect the presence or absence of grids: yes 7. Able to detect the presence or absence of detectors: yes 8. Dimensions: 380 x 530 x 2200mm(length x width x height) 9. Equipped with a potentiometer for measuring up and down movement X4 1.Movement:350mm-1850mm 2. Operation mode: manual and electric integration,at60mm/s 3. Cassette dimensions:17*17 detector 4.With AECionization chamber assembly position and grid insertion position 5. Power-off protection function:yes 6. Able to detect the presence or absence of grids: yes 7. Able to detect the presence or absence of detectors: yes 8. Detector rotation angle:-20°~90° 9.Dimensions: 760x530x2200mm(length x width x height) 10. Equipped with a potentiometer for measuring up and down movement X5 1.Movement:350mm-1850mm 2. Operation mode: manual and electric integration, at 60mm/s 3. Cassettedimensions: 17*17 detector 4. With AEC ionization chamber assembly position and grid insertion position 5. Power-off protection function: yes 6. Able to detect the presence or absence of grids: yes 7. Able to detect the presence or absence of detectors: yes 8. Detector rotation angle:-20°~90° 9. Dimensions:640x530*2260mm(length x width x height) 10. Equipped with a potentiometer for measuring up and down movement
Chest Radiograph Stand
safe and stable
Braking force:≥100N
Starting force: ≥100N
The moving range of the cassette along the column: 400- 1850 mm
Storage conditions and service life of the device
Ambient temperature: -20℃ ~ 55 ℃;
Relative humidity: 10% ~ 93%, including condensation;
Atmospheric pressure: 50kPa ~ 106kPa;
Equipped with self-developed ultra-clear large view size dynamic flat panel detector, 600 micron cesium iodide greatly improves X-ray conversion efficiency, unique amorphous silicon array and high-speed reading integrated circuit work closely, easily realize multi-frame rate fluoroscopy and high-definition spot film.
Large view size
Large view size
Fast Imaging Speed Switching
Simultaneous Exposure
Large view size
Digital Radiography
Applicable for all body positions.
Digital Contrast
Applicable for all regular and specific contrast examinations, It also supports replaying contrast video and select images of lesions for the diagnosis.
Digital Fluoroscopy
Applicable for all body position’s fluoroscopy examinations.
Have a more beautiful life!
A professional global provider of digital medical imaging devices
For more information, please click the official website.
Merkulove © Dentino Template All rights reserved Copyrights 2020